Casella-cel Fortin barometer Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Casella-cel Fortin barometer. Casella CEL Fortin barometer User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 11
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
HB3121
1
USER MANUAL
COPYRIGHT
The copyright in this document which contains information is vested in
CASELLA LIMITED. The contents of this document must not be used for
purposes other than that for which it has been supplied or reproduced or disclosed
wholly or in part without the prior written permission of CASELLA LIMITED.
CASELLA LIMITED
Regent House Telephone: +44 (0)1234 841441
Wolseley Road Facsimile: +44 (0)1234 841490
Kempston Telex: 827707
Bedford e-mail: [email protected]
MK42 7JY Webpage: http://www.casella.co.uk
FORTIN
BAROMETER
HB3121-02
Vista de página 0
1 2 3 4 5 6 ... 10 11

Resumo do Conteúdo

Página 1 - BAROMETER

HB31211USER MANUALCOPYRIGHTThe copyright in this document which contains information is vested inCASELLA LIMITED. The contents of this

Página 2

HB312110MAINTENANCENo attention should be necessary to a barometer except to dust it and to keep theadjusting screw clean and lightly oiled. The thre

Página 3

HB312111SPECIFICATIONEffective range: Ordinary Range model900 to 1060mb670 to 800mmHg26.4 to 31.2inHgAltitude up to: 450mVernier reads to: 0.1mb, 0.05

Página 4

HB31212CONTENTS PageINTRODUCTION... 3PRINCIPL

Página 5

HB31213INTRODUCTIONThe Fortin barometer is the most widely used type and can be found in manyindustrial laboratories, workshops, classrooms and meteor

Página 6 - ADJUSTING

HB31214INITIAL SET UPCHOOSING A SUITABLE LOCATIONThe room in which the barometer is due to hang should: -• Not be unduly warm.• Not be subject to va

Página 7

HB31215MOUNTING THE INSTRUMENTHaving chosen the best possible position for the barometer the glass windowedcase should be securely fixed to

Página 8

HB31216If the readings are to be corrected to mean sea level, the height of the cisternshould be accurately found and recorded as

Página 9

HB31217READING THE BAROMETERThe thermometer should always be read first since the presence of the observerwill cause the thermometer to al

Página 10

HB31218Where to view the vernier from

Página 11

HB31219The height of the mercury column can now be read on the scale using the vernier.The diagram below gives an example.For mmHg the reading is 1000

Comentários a estes Manuais

Sem comentários